FORT77(category10-web-server.html) - phpMan

FORT77(1P)                 POSIX Programmer's Manual                FORT77(1P)

PROLOG
       This  manual  page is part of the POSIX Programmer's Manual.  The Linux
       implementation of this interface may differ (consult the  corresponding
       Linux  manual page for details of Linux behavior), or the interface may
       not be implemented on Linux.
NAME
       fort77 - FORTRAN compiler (FORTRAN)
SYNOPSIS
       fort77 [-c][-g][-L directory]... [-O optlevel][-o outfile][-s][-w]
               operand...
DESCRIPTION
       The fort77 utility is the interface to the FORTRAN compilation  system;
       it   shall   accept   the  full  FORTRAN-77  language  defined  by  the
       ANSI X3.9-1978 standard. The system conceptually consists of a compiler
       and  link  editor.  The  files  referenced by operands are compiled and
       linked to produce an executable file. It  is  unspecified  whether  the
       linking  occurs entirely within the operation of fort77; some implemen-
       tations may produce objects that are not fully resolved until the  file
       is executed.
       If the -c option is present, for all pathname operands of the form file
       .f, the files:

              $(basename pathname.f).o
       shall be created or overwritten as the result  of  successful  compila-
       tion.   If  the  -c  option is not specified, it is unspecified whether
       such .o files are created or deleted for the file .f operands.
       If there are no options that prevent link editing (such as -c) and  all
       operands  compile and link without error, the resulting executable file
       shall be written into the file named by the -o option (if  present)  or
       to  the  file a.out.  The executable file shall be created as specified
       in the System Interfaces volume of  IEEE Std 1003.1-2001,  except  that
       the file permissions shall be set to:

              S_IRWXO | S_IRWXG | S_IRWXU
       and  that  the  bits  specified  by  the  umask of the process shall be
       cleared.
OPTIONS
       The fort77 utility shall conform to  the  Base  Definitions  volume  of
       IEEE Std 1003.1-2001,  Section  12.2, Utility Syntax Guidelines, except
       that:
        * The -l library operands have the format of options, but their  posi-
          tion  within a list of operands affects the order in which libraries
          are searched.
        * The order of specifying the multiple -L options is significant.
        * Conforming applications shall specify each option  separately;  that
          is,  grouping  option  letters (for example, -cg) need not be recog-
          nized by all implementations.
       The following options shall be supported:
       -c     Suppress the link-edit phase of  the  compilation,  and  do  not
              remove any object files that are produced.
       -g     Produce  symbolic information in the object or executable files;
              the nature of this information is unspecified, and may be  modi-
              fied by implementation-defined interactions with other options.
       -s     Produce object or executable files, or both, from which symbolic
              and other information not required for  proper  execution  using
              the  exec  family  of functions defined in the System Interfaces
              volume of IEEE Std 1003.1-2001 has been removed  (stripped).  If
              both -g and -s options are present, the action taken is unspeci-
              fied.
       -o  outfile
              Use the pathname outfile, instead of the default a.out, for  the
              executable  file  produced. If the -o option is present with -c,
              the result is unspecified.
       -L  directory
              Change the algorithm of searching for the libraries named in  -l
              operands  to  look in the directory named by the directory path-
              name before looking in the usual places. Directories named in -L
              options  shall  be searched in the specified order. At least ten
              instances of this option shall be supported in a  single  fort77
              command invocation. If a directory specified by a -L option con-
              tains a file named libf.a, the results are unspecified.
       -O  optlevel
              Specify the level of code optimization. If the optlevel  option-
              argument  is the digit '0', all special code optimizations shall
              be disabled. If it is the digit '1', the nature of the optimiza-
              tion  is unspecified. If the -O option is omitted, the nature of
              the system's default optimization is unspecified. It is unspeci-
              fied  whether  code generated in the presence of the -O 0 option
              is the same as that generated when -O is omitted. Other optlevel
              values may be supported.
       -w     Suppress warnings.

       Multiple instances of -L options can be specified.
OPERANDS
       An  operand is either in the form of a pathname or the form -l library.
       At least one operand of the pathname form shall be specified. The  fol-
       lowing operands shall be supported:
       file.f The pathname of a FORTRAN source file to be compiled and option-
              ally passed to the link editor. The filename operand shall be of
              this form if the -c option is used.
       file.a A  library  of object files typically produced by ar, and passed
              directly to  the  link  editor.  Implementations  may  recognize
              implementation-defined suffixes other than .a as denoting object
              file libraries.
       file.o An object file produced by fort77 -c and passed directly to  the
              link   editor.  Implementations  may  recognize  implementation-
              defined suffixes other than .o as denoting object files.

       The processing of other files is implementation-defined.
       -l  library
              (The letter ell.) Search the library named:

              liblibrary.a
       A library is searched when its name is encountered, so the placement of
       a  -l  operand is significant. Several standard libraries can be speci-
       fied in this manner, as described in the EXTENDED DESCRIPTION  section.
       Implementations  may  recognize  implementation-defined  suffixes other
       than .a as denoting libraries.

STDIN
       Not used.
INPUT FILES
       The input file shall be one of the following: a  text  file  containing
       FORTRAN  source  code;  an object file in the format produced by fort77
       -c; or a library of object files, in the format produced  by  archiving
       zero  or  more object files, using ar. Implementations may supply addi-
       tional utilities that produce files in these formats.  Additional input
       files are implementation-defined.
       A <tab> encountered within the first six characters on a line of source
       code shall cause the compiler to interpret the following  character  as
       if it were the seventh character on the line (that is, in column 7).
ENVIRONMENT VARIABLES
       The  following  environment  variables  shall  affect  the execution of
       fort77:
       LANG   Provide a default value for the  internationalization  variables
              that  are  unset  or  null.  (See the Base Definitions volume of
              IEEE Std 1003.1-2001, Section  8.2,  Internationalization  Vari-
              ables  for the precedence of internationalization variables used
              to determine the values of locale categories.)
       LC_ALL If set to a non-empty string value, override the values  of  all
              the other internationalization variables.
       LC_CTYPE
              Determine  the  locale  for  the  interpretation of sequences of
              bytes of text data as characters (for  example,  single-byte  as
              opposed to multi-byte characters in arguments and input files).
       LC_MESSAGES
              Determine  the  locale  that should be used to affect the format
              and contents of diagnostic messages written to standard error.
       NLSPATH
              Determine the location of message catalogs for the processing of
              LC_MESSAGES .
       TMPDIR Determine  the  pathname that should override the default direc-
              tory for temporary files, if any.

ASYNCHRONOUS EVENTS
       Default.
STDOUT
       Not used.
STDERR
       The standard error shall be used only for diagnostic messages. If  more
       than  one file operand ending in .f (or possibly other unspecified suf-
       fixes) is given, for each such file:

              "%s:\n", <file>
       may be written to allow identification of the diagnostic  message  with
       the appropriate input file.
       This utility may produce warning messages about certain conditions that
       do not warrant returning an error (non-zero) exit value.
OUTPUT FILES
       Object files, listing files, and executable files shall be produced  in
       unspecified formats.
EXTENDED DESCRIPTION
   Standard Libraries
       The  fort77  utility  shall  recognize the following -l operand for the
       standard library:
       -l f   This  library  contains  all   functions   referenced   in   the
              ANSI X3.9-1978  standard.  This operand shall not be required to
              be present to cause a search of this library.

       In the absence of options that inhibit invocation of the  link  editor,
       such as -c, the fort77 utility shall cause the equivalent of a -l f op-
       erand to be passed to the link editor as the last -l  operand,  causing
       it  to  be  searched  after  all  other  object files and libraries are
       loaded.
       It is unspecified whether the library libf.a exists as a regular  file.
       The  implementation  may accept as -l operands names of objects that do
       not exist as regular files.
   External Symbols
       The FORTRAN compiler and link editor shall support the significance  of
       external  symbols  up to a length of at least 31 bytes; case folding is
       permitted. The action taken upon  encountering  symbols  exceeding  the
       implementation-defined maximum symbol length is unspecified.
       The  compiler  and  link editor shall support a minimum of 511 external
       symbols per source or object file, and a minimum of 4095 external  sym-
       bols  total.  A diagnostic message is written to standard output if the
       implementation-defined limit is exceeded; other  actions  are  unspeci-
       fied.
EXIT STATUS
       The following exit values shall be returned:
        0     Successful compilation or link edit.
       >0     An error occurred.

CONSEQUENCES OF ERRORS
       When fort77 encounters a compilation error, it shall write a diagnostic
       to standard error and continue to compile other source  code  operands.
       It  shall  return  a  non-zero  exit  status, but it is implementation-
       defined whether an object module is  created.   If  the  link  edit  is
       unsuccessful,  a diagnostic message shall be written to standard error,
       and fort77 shall exit with a non-zero status.
       The following sections are informative.
APPLICATION USAGE
       None.
EXAMPLES
       The following usage example compiles xyz.f and creates  the  executable
       file foo:

              fort77 -o foo xyz.f
       The following example compiles xyz.f and creates the object file xyz.o:

              fort77 -c xyz.f
       The  following  example  compiles xyz.f and creates the executable file
       a.out:

              fort77 xyz.f
       The following example compiles xyz.f, links it with  b.o,  and  creates
       the executable a.out:

              fort77 xyz.f b.o
RATIONALE
       The  name of this utility was chosen as fort77 to parallel the renaming
       of the C compiler. The name f77 was not chosen to avoid  problems  with
       historical implementations. The ANSI X3.9-1978 standard was selected as
       a normative reference because the ISO/IEC  version  of  FORTRAN-77  has
       been superseded by the ISO/IEC 1539:1990 standard (Fortran-90).
       The file inclusion and symbol definition #define mechanisms used by the
       c99    utility    were    not    included    in    this    volume    of
       IEEE Std 1003.1-2001-even  though  they  are commonly implemented-since
       there is no requirement that the FORTRAN compiler use the C  preproces-
       sor.
       The   -onetrip   option   was   not   included   in   this   volume  of
       IEEE Std 1003.1-2001, even though many historical compilers support it,
       because it is derived from FORTRAN-66; it is an anachronism that should
       not be perpetuated.
       Some implementations produce compilation listings. This aspect of  FOR-
       TRAN has been left unspecified because there was controversy concerning
       the various methods proposed for implementing it:  a  -V  option  over-
       lapped  with historical vendor practice and a naming convention of cre-
       ating files with .l suffixes collided with historical lex  file  naming
       practice.
       There   is   no   -I   option   in  this  version  of  this  volume  of
       IEEE Std 1003.1-2001 to specify a  directory  for  file  inclusion.  An
       INCLUDE directive has been a part of the Fortran-90 discussions, but an
       interface supporting that standard is not in the current scope.
       It is noted that many FORTRAN compilers produce an object  module  even
       when  compilation  errors  occur;  during a subsequent compilation, the
       compiler may patch the object module rather than  recompiling  all  the
       code.  Consequently,  it  is  left to the implementor whether or not an
       object file is created.
       A reference to MIL-STD-1753 was  removed  from  an  early  proposal  in
       response  to a request from the POSIX FORTRAN-binding standard develop-
       ers. It was not the intention of the  standard  developers  to  require
       certification  of  the  FORTRAN compiler, and IEEE Std 1003.9-1992 does
       not specify the military standard or any special preprocessing require-
       ments.  Furthermore, use of that document would have been inappropriate
       for an international standard.
       The specification of optimization has been subject to  changes  through
       early  proposals. At one time, -O and -N were Booleans: optimize and do
       not optimize (with an unspecified default).  Some  historical  practice
       led this to be changed to:
       -O 0   No optimization.
       -O 1   Some level of optimization.
       -O  n  Other, unspecified levels of optimization.

       It is not always clear whether "good code generation" is the same thing
       as optimization. Simple optimizations of local actions do  not  usually
       affect the semantics of a program. The -O 0 option has been included to
       accommodate the very particular nature of scientific calculations in  a
       highly  optimized  environment;  compilers  make errors. Some degree of
       optimization is expected, even if it is not documented  here,  and  the
       ability  to  shut  it off completely could be important when porting an
       application. An implementation may treat -O 0 as "do less than  normal"
       if  it  wishes, but this is only meaningful if any of the operations it
       performs can affect the semantics of a program.  It is highly dependent
       on  the implementation whether doing less than normal is logical. It is
       not the intent of the -O 0 option to ask for inefficient  code  genera-
       tion,  but  rather to assure that any semantically visible optimization
       is suppressed.
       The specification of standard library access is consistent with  the  C
       compiler  specification.  Implementations  are  not  required  to  have
       /usr/lib/libf.a, as many historical implementations do, but if not they
       are required to recognize f as a token.
       External  symbol size limits are in normative text; conforming applica-
       tions need to know these limits. However, the  minimum  maximum  symbol
       length should be taken as a constraint on a conforming application, not
       on an implementation, and consequently the action taken  for  a  symbol
       exceeding  the  limit is unspecified. The minimum size for the external
       symbol table was added for similar reasons.
       The CONSEQUENCES OF ERRORS section clearly specifies  the  behavior  of
       the  compiler when compilation or link-edit errors occur.  The behavior
       of several historical implementations was examined, and the choice  was
       made  to  be  silent on the status of the executable, or a.out, file in
       the face of compiler or linker errors. If  a  linker  writes  the  exe-
       cutable  file,  then  links  it on disk with lseek()s and write()s, the
       partially linked executable file can be left on disk  and  its  execute
       bits  turned  off  if the link edit fails. However, if the linker links
       the image in memory before writing the file to disk, it need not  touch
       the executable file (if it already exists) because the link edit fails.
       Since both approaches are historical practice, a conforming application
       shall  rely  on the exit status of fort77, rather than on the existence
       or mode of the executable file.
       The -g and -s options are not specified as mutually-exclusive.  Histor-
       ically these two options have been mutually-exclusive, but because both
       are so loosely specified, it seemed appropriate to leave their interac-
       tion unspecified.
       The  requirement  that conforming applications specify compiler options
       separately is to reserve the multi-character option name space for ven-
       dor-specific compiler options, which are known to exist in many histor-
       ical implementations. Implementations are not  required  to  recognize,
       for example, -gc as if it were -g -c; nor are they forbidden from doing
       so. The SYNOPSIS shows all of the options separately to highlight  this
       requirement on applications.
       Echoing  filenames to standard error is considered a diagnostic message
       because it would otherwise be difficult to associate an  error  message
       with  the erring file. They are described with "may" to allow implemen-
       tations to use other methods of identifying files and to  parallel  the
       description in c99.
FUTURE DIRECTIONS
       A  compilation  system  based  on  the ISO/IEC 1539:1990 standard (For-
       tran-90) may be considered for a future version; it may have a  differ-
       ent utility name from fort77.
SEE ALSO
       ar,    asa,   c99,   umask(),   the   System   Interfaces   volume   of
       IEEE Std 1003.1-2001, exec
COPYRIGHT
       Portions of this text are reprinted and reproduced in  electronic  form
       from IEEE Std 1003.1, 2003 Edition, Standard for Information Technology
       -- Portable Operating System Interface (POSIX),  The  Open  Group  Base
       Specifications  Issue  6,  Copyright  (C) 2001-2003 by the Institute of
       Electrical and Electronics Engineers, Inc and The Open  Group.  In  the
       event of any discrepancy between this version and the original IEEE and
       The Open Group Standard, the original IEEE and The Open Group  Standard
       is  the  referee document. The original Standard can be obtained online
       at http://www.opengroup.org/unix/online.html .

IEEE/The Open Group                  2003                           FORT77(1P)