systemd.kill(5) - phpMan

SYSTEMD.KILL(5)                  systemd.kill                  SYSTEMD.KILL(5)

NAME
       systemd.kill - Process killing procedure configuration
SYNOPSIS
       service.service, socket.socket, mount.mount, swap.swap, scope.scope
DESCRIPTION
       Unit configuration files for services, sockets, mount points, swap
       devices and scopes share a subset of configuration options which define
       the killing procedure of processes belonging to the unit.
       This man page lists the configuration options shared by these five unit
       types. See systemd.unit(5) for the common options shared by all unit
       configuration files, and systemd.service(5), systemd.socket(5),
       systemd.swap(5), systemd.mount(5) and systemd.scope(5) for more
       information on the configuration file options specific to each unit
       type.
       The kill procedure configuration options are configured in the
       [Service], [Socket], [Mount] or [Swap] section, depending on the unit
       type.
OPTIONS
       KillMode=
           Specifies how processes of this unit shall be killed. One of
           control-group, process, mixed, none.
           If set to control-group, all remaining processes in the control
           group of this unit will be killed on unit stop (for services: after
           the stop command is executed, as configured with ExecStop=). If set
           to process, only the main process itself is killed. If set to
           mixed, the SIGTERM signal (see below) is sent to the main process
           while the subsequent SIGKILL signal (see below) is sent to all
           remaining processes of the unit's control group. If set to none, no
           process is killed. In this case, only the stop command will be
           executed on unit stop, but no process be killed otherwise.
           Processes remaining alive after stop are left in their control
           group and the control group continues to exist after stop unless it
           is empty.
           Processes will first be terminated via SIGTERM (unless the signal
           to send is changed via KillSignal=). Optionally, this is
           immediately followed by a SIGHUP (if enabled with SendSIGHUP=). If
           then, after a delay (configured via the TimeoutStopSec= option),
           processes still remain, the termination request is repeated with
           the SIGKILL signal (unless this is disabled via the SendSIGKILL=
           option). See kill(2) for more information.
           Defaults to control-group.
       KillSignal=
           Specifies which signal to use when killing a service. This controls
           the signal that is sent as first step of shutting down a unit (see
           above), and is usually followed by SIGKILL (see above and below).
           For a list of valid signals, see signal(7). Defaults to SIGTERM.
           Note that right after sending the signal specified in this setting
           systemd will always send SIGCONT, to ensure that even suspended
           tasks can be terminated cleanly.
       SendSIGHUP=
           Specifies whether to send SIGHUP to remaining processes immediately
           after sending the signal configured with KillSignal=. This is
           useful to indicate to shells and shell-like programs that their
           connection has been severed. Takes a boolean value. Defaults to
           "no".
       SendSIGKILL=
           Specifies whether to send SIGKILL to remaining processes after a
           timeout, if the normal shutdown procedure left processes of the
           service around. Takes a boolean value. Defaults to "yes".
SEE ALSO
       systemd(1), systemctl(1), journalctl(8), systemd.unit(5),
       systemd.service(5), systemd.socket(5), systemd.swap(5),
       systemd.mount(5), systemd.exec(5), systemd.directives(7), kill(2),
       signal(7)

systemd 219                                                    SYSTEMD.KILL(5)