mdadm.conf(5) - phpMan

MDADM.CONF(5)                 File Formats Manual                MDADM.CONF(5)

NAME
       mdadm.conf - configuration for management of Software RAID with mdadm
SYNOPSIS
       /etc/mdadm.conf
DESCRIPTION
       mdadm  is  a  tool  for creating, managing, and monitoring RAID devices
       using the md driver in Linux.
       Some common tasks, such as assembling all arrays, can be simplified  by
       describing the devices and arrays in this configuration file.

   SYNTAX
       The  file  should  be  seen as a collection of words separated by white
       space (space, tab, or newline).  Any word that beings with a hash  sign
       (#)  starts  a comment and that word together with the remainder of the
       line is ignored.
       Spaces can be included in a word using  quotation  characters.   Either
       single quotes (') or double quotes (") may be used.  All the characters
       from one quotation character to next identical character are  protected
       and will not be used to separate words to start new quoted strings.  To
       include a single quote it must be between double quotes.  To include  a
       double quote it must be between single quotes.
       Any  line  that  starts  with  white space (space or tab) is treated as
       though it were a continuation of the previous line.
       Empty lines are ignored, but otherwise  each  (non  continuation)  line
       must  start  with  a  keyword  as  listed below.  The keywords are case
       insensitive and can be abbreviated to 3 characters.
       The keywords are:
       DEVICE A device line lists the devices (whole  devices  or  partitions)
              that might contain a component of an MD array.  When looking for
              the components of an array, mdadm will scan  these  devices  (or
              any devices listed on the command line).
              The device line may contain a number of different devices (sepa-
              rated by spaces) and each device name can contain wild cards  as
              defined by glob(7).
              Also, there may be several device lines present in the file.
              Alternatively,  a  device line can contain either or both of the
              words containers and partitions.  The word containers will cause
              mdadm  to  look for assembled CONTAINER arrays and included them
              as a source for assembling further arrays.
              The word partitions will cause mdadm  to  read  /proc/partitions
              and  include  all  devices  and partitions found therein.  mdadm
              does not use the names from /proc/partitions but only the  major
              and  minor  device numbers.  It scans /dev to find the name that
              matches the numbers.
              If no DEVICE line is present, then "DEVICE  partitions  contain-
              ers" is assumed.
              For example:
              DEVICE /dev/hda* /dev/hdc*
              DEV    /dev/sd*
              DEVICE /dev/disk/by-path/pci*
              DEVICE partitions

       ARRAY  The  ARRAY lines identify actual arrays.  The second word on the
              line may be the name of the device where the array  is  normally
              assembled, such as /dev/md1 or /dev/md/backup.  If the name does
              not start with  a  slash  ('/'),  it  is  treated  as  being  in
              /dev/md/.   Alternately  the  word <ignore> (complete with angle
              brackets) can be given in which case any array which matches the
              rest  of  the line will never be automatically assembled.  If no
              device name is given,  mdadm  will  use  various  heuristics  to
              determine an appropriate name.
              Subsequent  words identify the array, or identify the array as a
              member of a group. If multiple identities are given, then a com-
              ponent  device  must  match  ALL  identities  to be considered a
              match.  Each identity word has a tag, and equals sign, and  some
              value.  The tags are:
           uuid=  The  value  should  be  a  128 bit uuid in hexadecimal, with
                  punctuation interspersed if desired.  This  must  match  the
                  uuid stored in the superblock.
           name=  The  value  should  be a simple textual name as was given to
                  mdadm when the array was created.  This must match the  name
                  stored  in  the superblock on a device for that device to be
                  included in the array.  Not all superblock  formats  support
                  names.
           super-minor=
                  The  value  is  an  integer which indicates the minor number
                  that was stored in the superblock when the  array  was  cre-
                  ated.  When  an array is created as /dev/mdX, then the minor
                  number X is stored.
           devices=
                  The value is a comma  separated  list  of  device  names  or
                  device  name  patterns.  Only devices with names which match
                  one entry in the list will be used to  assemble  the  array.
                  Note  that the devices listed there must also be listed on a
                  DEVICE line.
           level= The value is a RAID level.  This is  not  normally  used  to
                  identify an array, but is supported so that the output of
                  mdadm --examine --scan
                  can be use directly in the configuration file.
           num-devices=
                  The  value  is  the  number  of devices in a complete active
                  array.  As with level= this is mainly for compatibility with
                  the output of
                  mdadm --examine --scan.

           spares=
                  The  value  is a number of spare devices to expect the array
                  to have.  The sole use of this keyword and value is as  fol-
                  lows: mdadm --monitor will report an array if it is found to
                  have fewer than this number of spares when --monitor  starts
                  or when --oneshot is used.

           spare-group=
                  The  value  is  a  textual  name for a group of arrays.  All
                  arrays with the same spare-group name are considered  to  be
                  part  of  the  same  group.   The significance of a group of
                  arrays is that mdadm will, when monitoring the arrays,  move
                  a  spare drive from one array in a group to another array in
                  that group if the first array had a failed or missing  drive
                  but no spare.

           auto=  This option is rarely needed with mdadm-3.0, particularly if
                  use with the Linux kernel v2.6.28 or later.  It tells  mdadm
                  whether  to  use  partitionable  array  or non-partitionable
                  arrays and, in the  absence  of  udev,  how  many  partition
                  devices  to  create.   From  2.6.28 all md array devices are
                  partitionable, hence this option is not needed.
                  The value of this option can be "yes" or  "md"  to  indicate
                  that  a  traditional,  non-partitionable  md array should be
                  created, or "mdp", "part" or "partition" to indicate that  a
                  partitionable  md  array  (only  available  in linux 2.6 and
                  later) should be used.  This later set can also have a  num-
                  ber  appended  to  indicate  how  many  partitions to create
                  device files for, e.g.  auto=mdp5.  The default is 4.

           bitmap=
                  The option specifies a file in which a  write-intent  bitmap
                  should be found.  When assembling the array, mdadm will pro-
                  vide this file to the md driver as the  bitmap  file.   This
                  has  the  same  function  as  the  --bitmap-file  option  to
                  --assemble.

           metadata=
                  Specify the metadata format that the  array  has.   This  is
                  mainly recognised for comparability with the output of mdadm
                  -Es.

           container=
                  Specify that this array is a member array of some container.
                  The value given can be either a path name in /dev, or a UUID
                  of the container array.

           member=
                  Specify that this array is a member array of some container.
                  Each  type  of  container  has  some way to enumerate member
                  arrays, often a simple sequence number.  The  value  identi-
                  fies which member of a container the array is.  It will usu-
                  ally accompany a "container=" word.

       MAILADDR
              The mailaddr line gives an E-mail address that alerts should  be
              sent  to  when mdadm is running in --monitor mode (and was given
              the --scan option).  There should only be one MAILADDR line  and
              it  should  have only one address.  Any subsequent addresses are
              silently ignored.

       MAILFROM
              The mailfrom line (which can only be abbreviated to at  least  5
              characters) gives an address to appear in the "From" address for
              alert mails.  This can be useful if you want to explicitly set a
              domain,  as  the  default from address is "root" with no domain.
              All words on this line are catenated with  spaces  to  form  the
              address.
              Note  that  this  value cannot be set via the mdadm commandline.
              It is only settable via the config file.

       PROGRAM
              The program line gives the name of a  program  to  be  run  when
              mdadm --monitor detects potentially interesting events on any of
              the arrays that it is monitoring.  This program  gets  run  with
              two or three arguments, they being the Event, the md device, and
              possibly the related component device.
              There should only be one program line and it should be give only
              one program.

       CREATE The  create  line  gives default values to be used when creating
              arrays, new members of arrays, and device  entries  for  arrays.
              These include:

           owner=
           group= These  can  give  user/group  ids or names to use instead of
                  system defaults (root/wheel or root/disk).
           mode=  An octal file mode such as 0660 can be given to override the
                  default of 0600.
           auto=  This corresponds to the --auto flag to mdadm.  Give yes, md,
                  mdp, part -- possibly followed by a number of partitions  --
                  to indicate how missing device entries should be created.

           metadata=
                  The name of the metadata format to use if none is explicitly
                  given.  This can be useful to impose a  system-wide  default
                  of version-1 superblocks.

           symlinks=no
                  Normally when creating devices in /dev/md/ mdadm will create
                  a matching symlink from /dev/ with a  name  starting  md  or
                  md_.  Give symlinks=no to suppress this symlink creation.

           names=yes
                  Since Linux 2.6.29 it has been possible to create md devices
                  with a name like md_home rather than  just  a  number,  like
                  md3.   mdadm  will use the numeric alternative by default as
                  other tools that interact with md  arrays  may  expect  only
                  numbers.   If  names=yes  is  given in mdadm.conf then mdadm
                  will use a name when appropriate.   If  names=no  is  given,
                  then  non-numeric  md  device names will not be used even if
                  the default changes in a future release of mdadm.

           bbl=no By default, mdadm will reserve space for a  bad  block  list
                  (bbl)  on all devices included in or added to any array that
                  supports them.  Setting bbl=no will prevent this,  so  newly
                  added devices will not have a bad block log.

       HOMEHOST
              The  homehost  line  gives  a  default value for the --homehost=
              option to mdadm.  There should normally be only one  other  word
              on  the  line.   It  should either be a host name, or one of the
              special words <system>, <none> and  <ignore>.   If  <system>  is
              given,  then  the  gethostname(2)  systemcall is used to get the
              host name.  This is the default.
              If <ignore> is given, then a flag is set so that when arrays are
              being  auto-assembled  the  checking of the recorded homehost is
              disabled.  If <ignore> is given it is also possible to  give  an
              explicit  name which will be used when creating arrays.  This is
              the only case when there can be more that one other word on  the
              HOMEHOST  line.   If  there  are  other words, or other HOMEHOST
              lines, they are silently ignored.
              If <none> is given, then the default of using gethostname(2)  is
              over-ridden and no homehost name is assumed.
              When  arrays  are  created, this host name will be stored in the
              metadata.  When arrays are assembled using auto-assembly, arrays
              which  do not record the correct homehost name in their metadata
              will be assembled using a  "foreign"  name.   A  "foreign"  name
              alway ends with a digit string preceded by an underscore to dif-
              ferentiate it from any possible local name. e.g.  /dev/md/1_1 or
              /dev/md/home_0.
       AUTO   A  list  of names of metadata format can be given, each preceded
              by a plus or minus sign.  Also the word homehost is  allowed  as
              is all preceded by plus or minus sign.  all is usually last.
              When mdadm is auto-assembling an array, either via --assemble or
              --incremental and it finds metadata of a given type,  it  checks
              that metadata type against those listed in this line.  The first
              match wins, where all matches anything.  If  a  match  is  found
              that  was preceded by a plus sign, the auto assembly is allowed.
              If the match was preceded by a minus sign, the auto assembly  is
              disallowed.  If no match is found, the auto assembly is allowed.
              If  the  metadata  indicates that the array was created for this
              host, and the word homehost appears before any other match, then
              the array is treated as a valid candidate for auto-assembly.
              This  can  be  used  to  disable all auto-assembly (so that only
              arrays explicitly listed in mdadm.conf or on  the  command  line
              are assembled), or to disable assembly of certain metadata types
              which might be handled by other software.  It can also  be  used
              to disable assembly of all foreign arrays - normally such arrays
              are assembled but given a non-deterministic name in /dev/md/.
              The known metadata types are 0.90, 1.x, ddf, imsm.
              AUTO should  be  given  at  most  once.   Subsequent  lines  are
              silently  ignored.   Thus  an  earlier  config  file in a config
              directory will over-ride the setting in a later config file.

       POLICY This is used to specify what automatic behavior  is  allowed  on
              devices  newly  appearing  in  the  system and provides a way of
              marking spares that can be moved to other arrays as well as  the
              migration domains.  Domain can be defined through policy line by
              specifying  a  domain  name  for  a   number   of   paths   from
              /dev/disk/by-path/.  A device may belong to several domains. The
              domain of an array is a union of domains of all devices in  that
              array.   A  spare  can  be automatically moved from one array to
              another if the set of the destination array's  domains  contains
              all  the domains of the new disk or if both arrays have the same
              spare-group.
              To update hot plug configuration  it  is  necessary  to  execute
              mdadm --udev-rules command after changing the config file
              Keywords used in the POLICY line and supported values are:

              domain=
                     any arbitrary string
              metadata=
                     0.9 1.x ddf or imsm
              path=  file glob matching anything from /dev/disk/by-path
              type=  either disk or part.
              action=
                     include, re-add, spare, spare-same-slot, or force-spare
              auto=  yes, no, or homehost.

              The  action  item  determines the automatic behavior allowed for
              devices matching the path and type  in  the  same  line.   If  a
              device  matches  several  lines  with different actions then the
              most permissive will apply. The  ordering  of  policy  lines  is
              irrelevant to the end result.
              include
                     allows adding a disk to an array if metadata on that disk
                     matches that array
              re-add will include the device in the array if it appears to  be
                     a  current  member  or a member that was recently removed
                     and the array has  a  write-intent-bitmap  to  allow  the
                     re-add functionality.
              spare  as  above  and additionally: if the device is bare it can
                     become a spare if there is any array that it is a  candi-
                     date for based on domains and metadata.
              spare-same-slot
                     as  above  and  additionally if given slot was used by an
                     array that went degraded recently and the device  plugged
                     in has no metadata then it will be automatically added to
                     that array (or it's container)
              force-spare
                     as above and the disk will become a  spare  in  remaining
                     cases

       PART-POLICY
              This  is  similar to POLICY and accepts the same keyword assign-
              ments.  It allows a consistent set of  policies  to  applied  to
              each of the partitions of a device.
              A PART-POLICY line should set type=disk and identify the path to
              one or more disk devices.  Each partition on these disks will be
              treated  according to the action= setting  from this line.  If a
              domain is set in the line, then the domain associated with  each
              patition  will  be  based  on  the  domain,  but  with  "-partN"
              appended, when N is the partition number for the partition  that
              was found.

       SYSFS  The  SYSFS  line  lists  custom  values  of  MD  device's  sysfs
              attributes which will be stored in  sysfs  after  the  array  is
              assembled.  Multiple lines are allowed and each line has to con-
              tain the uuid or the name of the device to which it relates.
           uuid=  hexadecimal identifier of MD device. This has to  match  the
                  uuid stored in the superblock.
           name=  name  of  the MD device as was given to mdadm when the array
                  was created. It will be ignored if uuid is not empty.

       EXAMPLE
              DEVICE /dev/sd[bcdjkl]1
              DEVICE /dev/hda1 /dev/hdb1
              # /dev/md0 is known by its UUID.
              ARRAY /dev/md0 UUID=3aaa0122:29827cfa:5331ad66:ca767371
              # /dev/md1 contains all devices with a minor number of
              #   1 in the superblock.
              ARRAY /dev/md1 superminor=1
              # /dev/md2 is made from precisely these two devices
              ARRAY /dev/md2 devices=/dev/hda1,/dev/hdb1
              # /dev/md4 and /dev/md5 are a spare-group and spares
              #  can be moved between them
              ARRAY /dev/md4 uuid=b23f3c6d:aec43a9f:fd65db85:369432df
                         spare-group=group1
              ARRAY /dev/md5 uuid=19464854:03f71b1b:e0df2edd:246cc977
                         spare-group=group1
              # /dev/md/home is created if need to be a partitionable md array
              # any spare device number is allocated.
              ARRAY /dev/md/home UUID=9187a482:5dde19d9:eea3cc4a:d646ab8b
                         auto=part
              # The name of this array contains a space.
              ARRAY /dev/md9 name='Data Storage'
              POLICY domain=domain1 metadata=imsm path=pci-0000:00:1f.2-scsi-*
                         action=spare
              POLICY               domain=domain1                metadata=imsm
              path=pci-0000:04:00.0-scsi-[01]*
                         action=include
              #  One  domain comprising of devices attached to specified paths
              is defined.
              # Bare device matching first path will be made an imsm spare  on
              hot plug.
              #  If  more  than  one  array is created on devices belonging to
              domain1 and
              # one of them becomes degraded, then any imsm spare matching any
              path for
              # given domain name can be migrated.
              MAILADDR root AT mydomain.tld
              PROGRAM /usr/sbin/handle-mdadm-events
              CREATE group=system mode=0640 auto=part-8
              HOMEHOST <system>
              AUTO +1.x homehost -all
              SYSFS            name=/dev/md/raid5           group_thread_cnt=4
              sync_speed_max=1000000
              SYSFS                   uuid=bead5eb6:31c17a27:da120ba2:7dfda40d
              group_thread_cnt=4 sync_speed_max=1000000

SEE ALSO
       mdadm(8), md(4).

                                                                 MDADM.CONF(5)